25A Coherent X-ray Scattering

Frequently asked questions

Q: What is the q-range of SAXS detector for once acquistion?
A: About two order-of-magnitude (e.g. 0.005~0.5).

Q: Why is the energy of TPS 25A1 not an integer (e.g. 10 keV)?
A: The undulator is the X-ray source for TPS 25A1. Generally, we change the gap of undulator and select the suitable harmonics. The energy value with the highest flux and near the desired energy value will be selected. Therefore, the real energy values usually are not the integer (e.g. 10.005 keV).

Q: Why are the scattering patterns from the same sample different between TPS 25A1 and others?
A: The beamsize in FWHM at sample position of TPS 25A1 is 4μm by 5μm. Other SAXS beamlines provide the beamsize more than 200μm by 200μm. This means that the local micro-scale structure and sample homogeneity of the sample strongly affect the scattering patterns collected at TPS 25A1.

Q: How many exposure time should I set for the sample? Can I set 300 seconds for one acquisition?
A: Depends on your sample system. We suggest to use time-resolved data acquisition. For example, 1 second exposure time per frame and collecting multiple frames. This procedure can help you to identify the radiation damage on sample, and get better statistics after frame-combination if there is no radiation damage effect. Our data reduction program can output every single frame from the mutliple-frame datasets, and also perform frame combinations to get better statistics.

Q: Can I change the q-range or sample appartus during beamtime?
A: Yes, it takes time to change the q-range or sample appartus. If you want to change the condition, please inform us as soon as possible. It would be better to do this during our bussiness time.

Q: Can I do the data reduction at my own computer?
A: Yes, the (GI)-SAXS/(GI)-WAXS data reduction is Python-based program. Please see the 'Resource' for more information.

Find a Beamline

25A Home

Specifications

Techniques

Optical Layout

25A1 Endstations

Resource

FAQ

Staff

Publications

BL Schedule

25A2 Endstations

Gallery


 Contacts

Endstation

—+886-3-578-0281 Ext. 2251

BL 25A1 Spokesperson

Lin, Jhih-Min (林智敏)
lin.jm@nsrrc.org.tw
+886-3-578-0281 Ext. 7342

BL 25A1 Manager/Local Contact

Chen, Chun-Yu (陳軍佑)
chen.cy@nsrrc.org.tw
+886-3-578-0281 Ext. 7228

BL 25A2 Spokesperson

Huang, Yu-Shan (黃玉山)
jade@nsrrc.org.tw
+886-3-578-0281 Ext. 7321

BL 25A1 Manager/Local Contact

Tsai, Yi-Wei (蔡一葦)
tsai.yw@nsrrc.org.tw
+886-3-578-0281 Ext. 7215



Techniques

  • Coherent Diffraction Imaging (CDI)
  • X-ray Photon Correlation Spectroscopy (XPCS)
  • Small Angle X-ray Scattering (SAXS)

Disciplines

  • Materials science
  • Polymer and soft matter
  • Nanotechnology

General Information

  • Source: IU22
  • Energy Range: 5.5-20 keV
  • Focused Spot Size: 1 x 1 μm² or 10 x 10 μm²
  • Status: operational







National Synchrotron Radiation Research Center

101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu, Taiwan 30076

+886-3-578-0281