09A Temporally Coherent X-ray Diffraction

09A Construction Design Report ( click here to download)

  • Double Crystal Monochromator (DCM)

Specifications

Source:

ID, IU22

Monochromator:

crystal monochromator

DCM Si(111)

Energy Range:

5.6-25 keV for DCM

Energy Resolution:

ΔE/E~ 1.33 x 10-4 for DCM

Focused Spot Size:

400 x 700 μm2 (H x V)

Flux range (ph/s):

1012-1013 ph/s at sample position

Detector:

APD, Scintillation counter, Avalanche photodiode, PILATUS X-200K, Multi-crystal analyzer, Ionization chambers, Silicon Drift Detector (SDD)

Cryo Capability:

4-300 K

Pulse Length for Time-resolved Experiment:

30 ps

Find a Beamline

09A Home

Specifications

Endstations

Staff

BL Schedule

Optical Layout

Techniques

Publications

Gallery


 Contacts

BL Spokesperson

Weng-Chang Weng(翁世璋)
weng.sc@nsrrc.org.tw
Ext. 7366


BL Local Contact/Manager

BL Staff 

Song Yang(楊松)
yang.song@nsrrc.org.tw
Ext. 7303

BL Staff
Chia-Hung Hsu(徐嘉鴻)
chsu@nsrrc.org.tw

Ext. 7118

BL Staff
Shyh-Wei Chen(陳仕偉)
chen.shyhwei@nsrrc.org.tw
Ext. 7129

BL Staff
Yu-Sheng Chen(陳育聖)
chen.ys@nsrrc.org.tw
Ext. 8654


Techniques

  • Grazing incidence diffraction
  • Crystal truncation rods
  • Reciprocal space map
  • X-ray reflectivity
  • Resonant hard X-ray scattering
  • Pump/probe (X-ray diffraction) in tens of ps to ms range
  • General diffraction

Disciplines

  • Materials science
  • Structural dynamics of matter
  • X-ray optics

General Information

  • Source: IU22
  • Energy Range: 5.6-25 keV for DCM
  • Focused Spot Size: 600 x 700 μm² (H x V)
  • Status: operational







National Synchrotron Radiation Research Center

101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu, Taiwan 30076

+886-3-578-0281